NX11.0.0 MP03升级包即将发布!
最快明日提供下载地址。本次更新:Subject: Maintenance Pack 3 for NX 11.0.0 and SC 11.0.0To: All users of NX 11.0.0 and SC 11.0.0From: The Siemens PLM NX and Siemens PLM Simcenter Teams We are pleased to inform you that fixes are available for the problems listed below.A maintenance pack (MP3), built for installation on top of Windows64 and Linux64 images of NX 11.0.0 and SC 11.0.0, can now be downloaded from the Siemens PLM Download Server. This maintenance pack addresses the issues associated with the PR numbers and short descriptions listed in the tables below:
ReleasePR NumberShort Description
MP07543147Error opening a routing assembly
MP07686179Batch Processing with delay time does not work
MP07721010Error opening a routing assembly
MP07723695General WAVE Relinker doesn’t choose automatically IPE with multiple occurrences
MP07732325Changes to named references prevent saving
MP07734413NX crashes with an error when trying to open a part file
MP07740300Option Report Shortest Tool doesn’t include the field (OS) Offset.
MP07745527Option Report Shortest Tool doesn’t include the field (OS) Offset.
MP07760795Report shortest Tool length is not correct for Zlevel
MP08277216Error loading fem after replacing component
MP08288586PMI Appended Text, parameter link only possible to parameters of default group
MP08298245When in expression dialog, selecting objects in PNT does not work like NX10.0.2
MP08303559Measurement Failed with “Null Tag not allowed” Error when Measuring in Motion Application
MP08305515Editing an Interpart Expression name
MP08305522Expression dialog: after apply the new focus is on Visibility-Show
MP08305952Operating System Error
MP08306042Expression: New Expression ignores Active Group
MP08308133Unable to open part with error “An embedded object cannot be deleted in isolation”
MP08312278Repeat Command (F4) not available for AddOns
ReleasePR NumberShort Description
MP17497700Subordinate Design Elements removed when finishing Subset in NX.
MP17683194Teamcenter Attribute mapped in NX is not showing Display Name of LOV value
MP18293137Standard Part Assembly Constraints have invalid RM references to components
MP18313250NX 11.0.0 MP0 patch has hardcoded the wrong Title
ReleasePR NumberShort Description
MP27720828Need to have an identifier for Inverse Bending Lines in Profile List.
MP27765222Delete Deform for Deformable Component causes unexpected results
MP27770610Issues with Profile List Export regarding Weld Properties
MP27791871Fast RMS evaluation gives different solid stress results than standard evaluation
MP27793507Transitioning after Validate Basic Design and Dry run still results in an error
MP27795715Remove unused msvcr71.dll
MP27795722Update Xerces to V3.1.4
MP27803696Toolpath Contact Point differences between NX9 & NX10.0.3
MP27822709Unable to create stiffener - Invalid trailer found
MP28309087Need to be able to specify Item Type for Bending Templates (assemblies)
MP28310403"Remove Spools" only removes the Stock Features while the Components remain in the spool
MP28310774Generating Welds has an enormous performance impact when publishing welds during Save
MP28312501Creating/Editing Expression by NXOpen using ug_read_list formula fails in NX11
MP28314261Spline path shape change intermittently leaves control points in previous position
MP28523259NX crashes while exporting a part
ReleasePR NumberShort Description
MP37497700Subordinate Design Elements removed when finishing Subset in NX.
MP37694042Case sensitive expressions do not update correctly in Part Family spreadsheet
MP37696098Part Families - Expressions are changed when new number is assigned
MP37699435Save As fails with new name, after part name is stored in a tabular note
MP37701248NX Mono JT Export does not honor suppression
MP37714616LWSV of NX Mono JT Export Cuts through all components in view
MP37738607Vis Piece Components do not display in view when using Assembly Context Control
MP37742035Deleting a section cut component cuts the entire assembly
MP37743061Assembly Geometry does not display in view with non-geometric component
MP37767047Installation views do not display subset geometry when launched to TcVis
MP37780417Longer time delay displaying PMI Balloon note dialog
MP37787689NXMGR: Loading Assembly drawings in NX9: Error- Could not close O/S file
MP37795706Upgrade OpenSSL 1.0.2h to OpenSSL 1.0.2j
MP37795722Update Xerces to V3.1.4
MP37796048mom_mcs_goto differs from mom_pos in new drilling operations
MP37804634NX11 MoldWizard will not Pocket components from mm moldbase. NX 10 will.
MP37806185Tool position for material removal in CSE with 2 tracking points is not correct.
MP37806920Hidden NX Geometry Visible in TcVis
MP37818858Selection::SetSelectionStatusOfUserDefinedClass() does not add UDO class in NX11
MP37819177Geometry missing in PMI Model Views
MP37859513Getting an error while saving the part file.
MP37861358unable to stop a verify between GOTO points
MP37876936Assembly cannot be converted to CATIA Data in the .
MP37878201When - is executed, the NX data disappears.
MP38307669Part family spreadsheet seems corrupted
MP38308258NX freezes after some selections of the same component
MP38314383Bad curve distance given when part w/ coincident studio splines open in session
MP38314464GRIP &ATTVL ignores IFERR label and throws error message anyway in NX11
MP38314511GRIP &ATTVL ignores IFERR label and throws error message anyway in NX11
MP38317197OK Button not active after UF_UGMGR_reg_new_dataset_name callback running
MP38523116Unable to export to JT with CPU 100 usage in Linux Redhat 7.0
Windows update instructions
The files contained in nx-11.0.0.mp03.zip are provided as replacements for previously installed NX 11.0.0 and SC 11.0.0 products.
For the Windows64 platform, you should have at least 3.56 GB of free space to unzip this file.
Version NX 11.0.0 or SC 11.0.0 must be installed before updating to version NX 11.0.0.mp03. Please be aware that these updated MP files will be superseded by the next maintenance release or maintenance pack installed on your machines.To use this update, change to the directory where you unzipped the nx-11.0.0.mp03.zip file, make sure the entire set of new MP files have execute access.
Then do either one of the following: 1.Run 'run_ugsupdate.exe'This will read the %UGII_BASE_DIR% from the Registry and apply the update to the NX 11.0.0 or SC 11.0.0 folder.2.OR, you may follow the instructions below to run ugs_update.bat directly.Before running the script, please make sure the environment variable %UGII_BASE_DIR% is set to the base directory of the NX 11.0.0 or SC 11.0.0 release or set to the appropriate installed directory on your system.Then execute the 'ugs_update.bat' script.
For example:
Set UGII_BASE_DIR="C:\Program Files\Siemens\NX 11.0" cd nx1100_mp03
ugs_update.bat /v
The script supports a "/v" switch to turn on verbose messages while doing the file updates. The default operation of the script is non-verbose.
The script supports a "/d" switch. This will turn off the script confirmation prompts; useful for running the update in a batch job.
The script also supports a "/p" switch. This will turn off the initial confirmation prompt but it will display the final 'done' prompt. This is useful for running the update in a batch job where a final prompt is desired.
LINUX update instructions The files contained in nx-11.0.0.mp03.tar.gz are provided as replacements for previously installed NX 11.0.0 and SC 11.0.0 products.
For the Linux64 platform, you should have at least 4.63 GB of free space.
Version NX 11.0.0 or SC 11.0.0 must be installed before updating to version NX 11.0.0.mp03.Please be aware that these updated MP files will be superseded by the next maintenance release or maintenance pack installed on your machines.
To use this update, change to the directory where you extracted the nx-11.0.0.mp03.tar.gz distribution file, make sure the entire set of new MP files have execute access, then execute the “ugs_update” script.
cd nx1100_mp03chmod 555 *./ugs_update -v
The script will interrogate your installed NX or SC directory, and update the installed files.The normal operation of the script is non-verbose; stop to confirm default answers.
The update script supports 2 switches:-v = Display verbose messages.-d = Take all default answers (i.e.: script will not stop to ask questions).
After the MP update has run successfully, the following identifying text will be written into the system log of every NX and SC session:
"NX 11.0.0.33 MP3, 17Nov16.See Maintenance Pack letter for detailed list of fixes."
If you have any issues with the installation or support of these fixes, please contact your local Siemens PLM GTAC support group.
Sincerely,
The Siemens PLM NX and Siemens PLM Simcenter Teams
http://www.ugsnx.com/xwb/images/bgimg/icon_logo.png 该贴已经同步到 老叶的微博 不懂英文,都修复了什么问题 抢个座 抢个座 修复了什么啊? 支持一下{:handshake:} 坐等大版本升级? 修复了好多问题 感谢楼主分享 感谢楼主分享